Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Chem ; 18(1): 54, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38500132

RESUMO

Montelukast sodium (MLK) and Levocetirizine dihydrochloride (LCZ) are widely prescribed medications with promising therapeutic potential against COVID-19. However, existing analytical methods for their quantification are unsustainable, relying on toxic solvents and expensive instrumentation. Herein, we pioneer a green, cost-effective chemometrics approach for MLK and LCZ analysis using UV spectroscopy and intelligent multivariate calibration. Following a multilevel multifactor experimental design, UV spectral data was acquired for 25 synthetic mixtures and modeled via classical least squares (CLS), principal component regression (PCR), partial least squares (PLS), and genetic algorithm-PLS (GA-PLS) techniques. Latin hypercube sampling (LHS) strategically constructed an optimal validation set of 13 mixtures for unbiased predictive performance assessment. Following optimization of the models regarding latent variables (LVs) and wavelength region, the optimum root mean square error of cross-validation (RMSECV) was attained at 2 LVs for the 210-400 nm spectral range (191 data points). The GA-PLS model demonstrated superb accuracy, with recovery percentages (R%) from 98 to 102% for both analytes, and root mean square error of calibration (RMSEC) and prediction (RMSEP) of (0.0943, 0.1872) and (0.1926, 0.1779) for MLK and LCZ, respectively, as well bias-corrected mean square error of prediction (BCMSEP) of -0.0029 and 0.0176, relative root mean square error of prediction (RRMSEP) reaching 0.7516 and 0.6585, and limits of detection (LOD) reaching 0.0813 and 0.2273 for MLK and LCZ respectively. Practical pharmaceutical sample analysis was successfully confirmed via standard additions. We further conducted pioneering multidimensional sustainability evaluations using state-of-the-art greenness, blueness, and whiteness tools. The method demonstrated favorable environmental metrics across all assessment tools. The obtained Green National Environmental Method Index (NEMI), and Complementary Green Analytical Procedure Index (ComplexGAPI) quadrants affirmed green analytical principles. Additionally, the method had a high Analytical Greenness Metric (AGREE) score (0.90) and a low carbon footprint (0.021), indicating environmental friendliness. We also applied blueness and whiteness assessments using the high Blue Applicability Grade Index (BAGI) and Red-Green-Blue 12 (RGB 12) algorithms. The high BAGI (90) and RGB 12 (90.8) scores confirmed the method's strong applicability, cost-effectiveness, and sustainability. This work puts forward an optimal, economically viable green chemistry paradigm for pharmaceutical quality control aligned with sustainable development goals.

2.
J AOAC Int ; 107(1): 146-157, 2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-37494481

RESUMO

BACKGROUND: Drug impurities are now seen as a major threat to the production of pharmaceuticals around the world and a major part of the global contamination problem, especially when it comes to carcinogenic impurities. OBJECTIVE: We present the first spectrophotometric strategy based on a combination of univariate and multivariate methods as impurity profiling methods for the estimation of lignocaine (LIG) and fluorescein (FLS) with their carcinogenic impurities: 2,6-xylidine (XYL) and benzene-1,3-diol (BZD). METHOD: The data processing strategy depends on overcoming unresolved bands by employing five affordable, accurate, selective, and sensitive methods. The methods applied were a direct UV univariate spectrophotometric analysis (D0) and four multivariate chemometric methods, including classical least squares (CLS), principal component regression (PCR), partial least squares (PLS), and genetic algorithm (GA-PLS). FLS analysis (1-16 µg/mL) was performed using the D0 method at 478 nm; then, the application of the ratio subtraction method (RSM) allowed the removal of interference caused by the FLS spectrum. From the resulting ratio spectra, LIG, XYL, and BZD can be efficiently determined by chemometrics. The calibration set was carefully selected at five concentration levels using a partial factorial training design, resulting in 25 mixtures with central levels of 160, 40, and 3 µg/mL for LIG, XYL, and BZD, respectively. Another 13 samples were applied to validate the predictive ability. RESULTS: The statistical parameters demonstrated exceptional recoveries and smaller prediction errors, confirming the experimental model's predictive power. CONCLUSIONS: The proposed approach was effectively tested using newly FDA-approved LIG and FLS pharmaceutical preparation and aqueous humor. Additionally, it was effectively assessed for whiteness, greenness, and sustainability using five assessment tools. HIGHLIGHTS: With its remarkable analytical performance, sustainability, affordability, simplicity, and cost-efficiency, the proposed strategy is an indispensable tool for quality control and in situ analysis in little-equipped laboratories, increasing the proposed approach's surveillance ability.


Assuntos
Quimiometria , Neoplasias , Humanos , Humor Aquoso , Espectrofotometria/métodos , Análise dos Mínimos Quadrados , Calibragem
3.
Spectrochim Acta A Mol Biomol Spectrosc ; 302: 123161, 2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-37478754

RESUMO

A novel diffuse reflectance fourier transform infrared spectroscopic method accompanied by chemometrics was optimized to fulfill the white analytical chemistry and green analytical chemistry principles for the quantification of cinnarizine and piracetam for the first time without any prior separation in their challenging pharmaceutical preparation, which has a pretty substantial difference in the concentration of cinnarizine/piracetam (1:16). Furthermore, the suggested method was used for cinnarizine/piracetam dissolution testing as an effective alternative to traditional methods. For the cinnarizine/piracetam dissolution tests, we used a dissolution vessel with 900 mL of phosphate buffer pH 2.5 at 37 °C ± 0.5 °C, then the sampling was carried out by frequent withdrawal of 20 µl samples from the dissolution vessel at a one-minute interval, over one hour, then representative fourier transform infrared spectra were recorded. To create a partial-least-squares regression model, a fractional factorial design with 5 different levels and 2 factors was used. This led to the creation of 25 mixtures, 15 as a calibration set and 10 as a validation set, with varying concentration ranges: 1-75 and 16-1000 µg/mL for cinnarizine/piracetam, respectively. Upon optimization of the partial-least-squares regression model, in terms of latent variables and spectral region, root mean square error of cross-validation of 0.477 and 0.270, for cinnarizine/piracetam respectively, were obtained. The optimized partial-least-squares regression model was further validated, providing good results in terms of recovery% (around 98 to 102 %), root mean square error of prediction (0.436 and 3.329), relative root mean square error of prediction (1.210 and 1.245), bias-corrected mean square error of prediction (0.059 and 0.081), and limit of detection (0.125 and 2.786) for cinnarizine/piracetam respectively. Ultimately, the developed method was assessed for whiteness, greenness, and sustainability using five assessment tools. the developed method achieved a greener national environmental method index and complementary green analytical procedure index quadrants with higher eco-scale assessment scores (91), analytical greenness metric scores (0.87), and red-greenblue 12 algorithm scores (89.7) than the reported methods, showing high practical and environmental acceptance for quality control of cinnarizine/piracetam.


Assuntos
Cinarizina , Piracetam , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Cinarizina/análise , Quimiometria , Controle de Qualidade , Análise dos Mínimos Quadrados
4.
J AOAC Int ; 105(6): 1755-1761, 2022 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-35758559

RESUMO

BACKGROUND: Tamsulosin (TAM) and dutasteride (DUT) are ranked among the most frequently prescribed therapies in urology. Interestingly, studies have also been carried out on TAM/DUT in terms of their ability to protect against recent COVID-19. However, very few studies were reported for their simultaneous quantification in their combined dosage form and were mainly based on chromatographic analysis. Subsequently, it is very important to offer a simple, selective, sensitive, and rapid method for the quantification of TAM and DUT in their challenging dosage form. OBJECTIVE: In this study, a new chemometrically assisted ultraviolet (UV) spectrophotometric method has been presented for the quantification of TAM and DUT without any prior separation. METHOD: For the calibration set, a partial factorial experimental design was used, resulting in 25 mixtures with central levels of 20 and 25 µg/mL for TAM and DUT, respectively. In addition, to assess the predictive ability of the developed approaches, another central composite design of 13 samples was used as a validation set. Post-processing by chemometric analysis of the recorded zero-order UV spectra of these sets has been applied. These chemometric approaches include partial least-squares (PLS) and genetic algorithm (GA), as an effective variable selection technique, coupled with PLS. RESULTS: The models' validation criteria displayed excellent recoveries and lower errors of prediction. CONCLUSIONS: The proposed models were effectively used to determine TAM/DUT in their combined dosage form, and statistical comparison with the reported method revealed satisfactory results. HIGHLIGHTS: Overall, this work presents powerful simple, selective, sensitive, and precise methods for simultaneous quantification of TAM/DUT in their dosage form with satisfactory results. The predictive ability and accuracy of the developed methods offer the opportunity to be employed as a quality control technique for the routine analysis of TAM/DUT when chromatographic instruments are not available.


Assuntos
COVID-19 , Projetos de Pesquisa , Humanos , Dutasterida , Tansulosina , Espectrofotometria Ultravioleta/métodos , Análise dos Mínimos Quadrados , Calibragem , Preparações Farmacêuticas , Espectrofotometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...